If batteries are being used, connect the batteries (17 AH max.) to connector P2 located to the left center of the FC-PSM(E) Supply/Battery Charger Module. Complete the installation by connecting the AC power wires to the Hot, Neutral and Earth terminals of TB1 on the Power Supply/Battery Charger Module. Note that the Transformer cable connector is keyed to prevent connection. Plug the XRM-24(E) Transformer cable assembly into connector P1 which is located in the lower left corner of the Power Supply/Battery Charger Module. This connection is in order to provide proper lightning and transient protection for the panel. Connect a wire from a solid earth ground to one of the Transformer mounting studs and tighten the nut. Do not tighten one nut until the next step. Secure Transformer to the studs with the two supplied nuts. Transformer should be oriented so the cable assembly is the left as illustrated below. Position XRM-24(E)Transformer Assembly over mounting studs. Fire-Lite Voice Evac 64,901 views 126 Dislike Share Save weatherdan882002 2.38K subscribers Subscribe A requested vid. Transformer Installation Locate two threaded mounting studs in the bottom left corner of the backbox (refer to backbox illustration below).
#FIRELITE VOICE EVAC INSTALL#
2, 3 Standoff 1, 2, 3 factory jumper installing the Module 2, 3 Standoff 1, 2, 3 Standoff Power Supply/ Charger Module Evacuation Control Panel Circuit Board Remove two mounting screws from main board upper and lower left corners Main Circuit Board Install four metal standoffs by screwing place (note two different lengths) Install FC-PSM(E) Module and with four screws Circuit Main Circuit Board Backbox Mounting Rails Backbox Mounting Rails Backbox Mounting Rails Make certain all power (AC and DC) is removed before any connections are made. Continue with the FC-PSM(E) transformer installation as described on the following page.
#FIRELITE VOICE EVAC PASSWORD#
Please use the Forgot Password feature on the Login screen in order to retrieve your User ID and reset your password. It is important that module be secured with the metal screws in order to help protect against lightning electrical transients. This email address already exists in the system. Secure the FC-PSM(E) to the standoffs using the two screws removed in Step 1 and two supplied screws. UPC 783008105266 is associated with product Fire-Lite Alarms / Honeywell - ACC-25/50 - Audio Cmnd Cntr Voice Evac Pnl, find 783008105266 barcode image. Make certain the pins are properly aligned to prevent bending or any pins. Carefully align connector J1 on the FC-PSM(E) Power Supply/Battery Charger Module with connector P7 on the main board and press the FC-PSM(E) securely into place. The customer also has existing Bose speakers that they want to play the message as well. These speaker strobes are currently running on 25v. The customer has existing speakers in the field with a strobe built in as per normal. P7 is located on the bottom left corner the main circuit board (refer to illustration below). Hey everyone I am installing a Firelite MS-9600 and replacing a Evax voice system with a Firelite ECC 50/100 at a site. The SKE-Series system consists of two different models, the SKE-450 and SKE-450-ZN4. The mounting studs are located to the far left on each rail (refer to illustrations on following Remove the factory installed jumper from connector P7 of the main circuit board. Silent Knight SKE-450 Voice Evacuation Control Panel Silent Knight SKE450 - Voice Evacuation System The SKE-Series Voice Evacuation system provides 50 watts of output power. Install the two supplied long metal standoffs by screwing them onto the threaded mounting studs in the top and bottom rails in the back box. Install two short metal standoffs, which are supplied with the FC-PSM(E) Power Supply/Battery Charger Module, by screw- them into the top left and bottom left corners of the main circuit board, where the screws were removed in Step 1.
Power Supply/Battery Charger Module Installation Remove two mounting screws from the top left and bottom left corners of the main circuit board (largest circuit board closest to cabinet back). Evacuation Control Panel Power Supply/Battery Module Installation Drawing 50612 Rev B 8/8/97 ECN 97-303 Make certain all power (AC and DC) is removed before any connections are made. In addition to supplying operating the modules are capable of charging 7 AH to 17 AH batteries.
At JMAC Supply, we carry fire alarm control panels that are capable of evacuating and/or messaging occupants in an emergency. The FC-PSME requires VAC, 50 Hz, 0.5 amps. Fire-Lite ECC-50DA Distributed (Remote) Audio Amplifier, 50W, 120VAC Our Price: 1,629.43 1 Add audio notifications to a fire alarm control panel using fire alarm voice evacuation panels. Optional amplifier can be configured as a backup in the event the primary amplifier fails.The FC-PSM(E) Power Supply/Battery Charger Module can be used to stand-alone power to the Voice Evacuation Control Panel.50 watts of 25 V audio power (expandable to 100 watts) RMS.Modular design for maximum system flexibility and easy expansion.UL Listed to UL2572 Communication (Control Units Mass Notification Systems).